- The Envirolyte ELA-400 is a next step in our development of automated Envirolyte machines to suite our customer's needs for automation in the process of generation of activated solutions.
- The Envirolyte ELA-400 has been designed for production of Neutral Anolyte only.
|
 Envirolyte ELA-400 |
- Some automation and easy operating procedures give the added benefits to rapid elivery of safe and fast acting disinfectan - Neutral Anolyte.
- The strenght of Neutral Anolyte in terms of active chlorine concentration can be adjasted by current setting.
|
|
|
|
I Features of Envirolyte ELA-400 |
|
- The control system of ELA-400 units is simple and easy to operate. It can be altered to suit different applications and conditions.
- A flow controller is installed in the Hydraulical part to shut the Envirolyte unit if there is interruption of water supply and to start the unit as soon as water flow resumes.
|
 Electrical enclosure of ELA-400 |
- The enclosures are made of non-corrosive materials. Tubes and connectors are of EPDM/PVDF plastics and are highly resistant against aggressive solutions.
- All input and output connectors are located on the sides of the boxes to allow them wall-mountable.
|
 Hydraulic enclosure of ELA-400 |
- A simple on/off switch with power indicator starts and stops the ELA-400 units manually.
- Level switches enable to start and stop ELA-400 unit automatically.
- Alarm is inbuilt in the unit but can be arranged in any remote area through external connection.
|
II Specifications of Envirolyte ELA-400 units |
|
| Envirolyte ELA-400 units |
Code ELA |
| Hydraulic enclosure: |
400x300x180mm (hxwxd) |
| Electrical enclosure: |
400x300x180mm (hxwxd) |
| Power source: |
230 / 110 VAC ±10% |
| Power consumption: |
470 WT |
| Max. output capacity: |
400L per day of neutral anolyte |
| Automation: |
start/stop by means of two level switches |
| Flow controller: |
flow/no-flow protection with alarm and automatic start/shutdown |
| Input valve: |
-24vDC/6BAR |
| Weight: |
23 Kg |
Evirolyte ELA-400 unit with ORP meter to start and stop the unit depending on the ORP reading in the treated water
Envirolyte ELA-400 unit designed in compliance with IP-66 for treatment of cooling waters
|
| |
|
Neutral Anolyte |
|
|
| Regime |
active chlorine mg/l |
pH |
ORP mV
(redox-potential) |
Type of Envirolyte generator |
| Neutral Anolyte |
~500-700 |
~7.5-8.5 |
~700-900 |
ELA-400 |
|
|
|
III Spares & Service Parts |
|
All of the system components are modular for easy servicing & replacement
|
|
|
Application: Cooling water for plastic moulds antibacteria / antialgae / antibiofilm treatment (Finland)
|
|
For Envirolyte ELA-400 instruction details or applications please send Your enquiry.
|